Elmwood PD Series

Elmwood Thermal Cut Offs are available with variety of package options.

PD-A and PD-B package consists of thermal fuse into plastic insulating mounting case.

PD SERIES TEMPERATURE RATING

PDxxx-A10

MODEL Tf (FUNCTIONING OPEN TEMPERATURE) Th (HOLDING TEMPERATURE) Tm (MAXIMUM OVERSHOOT TEMPERATURE) SAFETY APPROVAL
PD070-A10 72 162 +0/-4℃ 57 115 UL, C-UL
PD076-A10 77 171 +0/-4℃ 62 150
PD081-A10 84 183 +0/-4℃ 69 115
PD088-A10 90 194 +0/-4℃ 75 150
PD090-A10 93 199 +0/-6℃ 78 315
PD098-A10 100 212 +0/-4℃ 85 130
PD103-A10 104 219 +0/-4℃ 89 315
PD108-A10 109 228 +0/-4℃ 94 315
PD115-A10 117 243 +0/-4℃ 102 130
PD118-A10 121 250 +0/-6℃ 106 315
PD125-A10 128 262 +0/-4℃ 113 180

 

PDxxx-B10

MODEL Tf (FUNCTIONING OPEN TEMPERATURE) Th (HOLDING TEMPERATURE) Tm (MAXIMUM OVERSHOOT TEMPERATURE) SAFETY APPROVAL
PD070-B10 72 162 +0/-4℃ 57 115 UL, C-UL
PD076-B10 77 171 +0/-4℃ 62 150
PD081-B10 84 183 +0/-4℃ 69 115
PD088-B10 90 194 +0/-4℃ 75 150
PD090-B10 93 199 +0/-6℃ 78 315
PD098-B10 100 212 +0/-4℃ 85 130
PD103-B10 104 219 +0/-4℃ 89 315
PD108-B10 109 228 +0/-4℃ 94 315
PD115-B10 117 243 +0/-4℃ 102 130
PD118-B10 121 250 +0/-6℃ 106 315
PD125-B10 128 262 +0/-4℃ 113 180


Tf (FUNCTIONING OPEN TEMPERATURE)
The maximum temperature at which the thermal cut offs changes its state of conductivity
to open circuit with detection current as the only load.

Th (HOLDING TEMPERATURE)
The maximum temperature at which,when applying no electrical load to the thermal cut offs,
the state of conductivity will not change during a period of 168 hours.

Tm (MAXIMUM OVERSHOOT TEMPERATURE)
The maximum temperature of thermal cut offs, having changed its state of conductivity, can be maintained for 10 minutes
during which its mechanical and electrical properties will not be impaired.

ELECTRICAL RATINGS

PDxxx-A10

SAFETY APPROVAL VOLTAGE (AC) RESISTIVE CURRENT
(Vr) (Ir) (Ib)
UL, C-UL 120V / 250V 16.7A 25A

PDxxx-B10

SAFETY APPROVAL VOLTAGE (AC) RESISTIVE CURRENT
(Vr) (Ir) (Ib)
UL, C-UL 120V / 250V 16.7A 25A


<Notes> All products shall comply with IEC-60691 - FOR ED. 3.0 AMENDMENT 2.